Steps for Connection:

1. Align the mechanical load with the shaft and tighten it with the help of a wrench .

2. Select the cable colour button (red).

3. Connect L31 with CC (current coil) of the wattmeter on the left side .

4. Connect common point of wattmeter with u1.

5. Select the cable colour (green) .

6. Connect PC (potential coil) with v1 .

7. Connect L32 with v1 .

8. Select the cable colour (blue) .

9. Connect L33 with CC of the wattmeter on the right side.

10. Connect the common point of the wattmeter with w1 .

11. Select the cable colour (green).

12. Connect PC with v1 .

13. Select the cable colour (green) .

14. Connect L32 with one terminal of the voltmeter .

15. Select the cable colour (blue) .

16. Connect L33 with the other terminal of the voltmeter.

17. Select the cable colour (black) .

18. Connect ammeter between u2 and v2 .

19. Short v2 and w2 .

20. Click the check button and if the connection is correct, click OK .

21. If the connection is wrong, follow the error message displayed and correct the connection .

22. Select 1 on the two way switch on the left hand side of the panel .

23. Switch ON the MCB and click the start button .

24. Switch ON the second MCB .

25. Click ‘b’ on the three way switch to select the variable voltage .

26. Select 1 on the next two way switch .

27. Select voltage with the voltage regulator knob .

28. Note the readings of voltmeter, ammeter and wattmeter .

For video tutorial click the link below

LINK

Copyright IIT GUWAHATI | Developed By CSE DEPARTMENT