Shakshat Virtual Lab

INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI

  • Home
  • About
  • People
  • Contact Us


No-Load Test

  • Introduction
  • Theory
  • Procedure
  • Experiment
  • Sovled Examples
  • Quiz



Steps for Connection:

1. Select the cable colour button (red) .

2. Connect L1 with CC (current coil) of the wattmeter on the left side.

3. Connect common point of wattmeter with u1 .

4. Select the cable colour (green) .

5. Connect PC (potential coil) with v1 .

6. Connect L2 with v1 .

7. Select the cable colour (blue) .

8. Connect L3 with CC of the wattmeter on the right side .

9. Connect the common point of the wattmeter with w1 .

10. Select the cable colour (green) .

11. Connect PC with v1 .

12. Select the cable colour (black) .

13. Connect ammeter between u2 and v2 .

14. Short v2 and w2 .

15. Select the cable colour (green) .

16. Connect L2 with one terminal of the voltmeter .

17. Select the cable colour (blue) .

18. Connect L3 with the other terminal of the voltmeter .

19. Click the check button and if the connection is correct, click OK .

20. If the connection is wrong, follow the error message displayed and correct the connection .

21. Select 1 on the two way switch on the left hand side of the panel .

22. Switch ON the MCB and click the start button .

23. Switch ON the second MCB .

24. Click ‘b’ on the three way switch to select the variable voltage .

25. Select 1 on the next two way switch .

26. Select voltage with the voltage regulator knob .

27. Note the readings of voltmeter, ammeter and wattmeter .

For video tutorial click the link below

LINK

Copyright IIT GUWAHATI | Developed By CSE DEPARTMENT